HL4RPV-50W | HL4RPV-50
HL4-50, HELIAX® Plenum Rated Air Dielectric Coaxial Cable, corrugated copper, 1/2 in, off white PVC jacket
Specifications
Product classification
Product Type | Air coaxial cable |
Product Brand | HELIAX® |
Product Series | HL4-50A |
General specifications
Product Number | 520095502/00 |
Flexibility | Standard |
Jacket Color | Off-white |
Performance Note | Attenuation values typical, guaranteed within 5% |
Dimensions
Diameter Over Jacket | 15.367 mm | 0.605 in |
Inner Conductor OD | 4.801 mm | 0.189 in |
Outer Conductor OD | 13.843 mm | 0.545 in |
Nominal Size | 1/2 in |
Electrical specifications
Cable Impedance | 50 ohm ±2 ohm |
Capacitance | 75.459 pF/m | 23 pF/ft |
dc Resistance, Inner Conductor | 1.476 ohms/km | 0.45 ohms/kft |
dc Resistance, Outer Conductor | 1.903 ohms/km | 0.58 ohms/kft |
dc Test Voltage | 4000 V |
Inductance | 0.19 µH/m | 0.058 µH/ft |
Insulation Resistance | 100000 MOhms-km |
Jacket Spark Test Voltage (rms) | 5000 V |
Operating Frequency Band | 1 – 8800 MHz |
Peak Power | 40 kW |
Power Attenuation | 2.325000047683716 |
Pulse Reflection | 0.5% |
Velocity | 88 % |
Material specifications
Dielectric Material | PE spline |
Jacket Material | PVC |
Inner Conductor Material | Copper-clad aluminum wire |
Outer Conductor Material | Corrugated copper |
Mechanical specifications
Minimum Bend Radius, multiple Bends | 127 mm | 5 in |
Number of Bends, minimum | 15 |
Number of Bends, typical | 25 |
Tensile Strength | 113 kg | 249.122 lb |
Bending Moment | 5.423 N-m | 4 ft lb |
Flat Plate Crush Strength | 1.429 kg/mm | 80 lb/in |
Environmental specifications
Installation temperature | -5 °C to +60 °C (+23 °F to +140 °F) |
Operating Temperature | -20 °C to +80 °C (-4 °F to +176 °F) |
Storage Temperature | -20 °C to +85 °C (-4 °F to +185 °F) |
Attenuation, Ambient Temperature | 20 °C | 68 °F |
Average Power, Ambient Temperature | 40 °C | 104 °F |
Average Power, Inner Conductor Temperature | 100 °C | 212 °F |
Fire Retardancy Test Method | NFPA 262/CATVP/CMP |
Packaging and weights
Cable weight | 0.253 kg/m | 0.17 lb/ft |
Regulatory compliance/certifications
Agency | Classification |
CHINA-ROHS
![]() |
Below maximum concentration value |
c(ETL)us Certification
![]() |
CATVP/CMP |
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
ROHS | Compliant |
UK-ROHS | Compliant |
UL/ETL Certification
![]() |
CATVP/CMP |
REACH-SVHC | Compliant as per SVHC revision on www.andrew.com/ProductCompliance |
Product classification
Product Type | Air coaxial cable |
Product Brand | HELIAX® |
Product Series | HL4-50A |
General specifications
Product Number | 520095502/00 |
Flexibility | Standard |
Jacket Color | Off-white |
Performance Note | Attenuation values typical, guaranteed within 5% |
Dimensions
Diameter Over Jacket | 15.367 mm | 0.605 in |
Inner Conductor OD | 4.801 mm | 0.189 in |
Outer Conductor OD | 13.843 mm | 0.545 in |
Nominal Size | 1/2 in |
Electrical specifications
Cable Impedance | 50 ohm ±2 ohm |
Capacitance | 75.459 pF/m | 23 pF/ft |
dc Resistance, Inner Conductor | 1.476 ohms/km | 0.45 ohms/kft |
dc Resistance, Outer Conductor | 1.903 ohms/km | 0.58 ohms/kft |
dc Test Voltage | 4000 V |
Inductance | 0.19 µH/m | 0.058 µH/ft |
Insulation Resistance | 100000 MOhms-km |
Jacket Spark Test Voltage (rms) | 5000 V |
Operating Frequency Band | 1 – 8800 MHz |
Peak Power | 40 kW |
Power Attenuation | 2.325000047683716 |
Pulse Reflection | 0.5% |
Velocity | 88 % |
Material specifications
Dielectric Material | PE spline |
Jacket Material | PVC |
Inner Conductor Material | Copper-clad aluminum wire |
Outer Conductor Material | Corrugated copper |
Mechanical specifications
Minimum Bend Radius, multiple Bends | 127 mm | 5 in |
Number of Bends, minimum | 15 |
Number of Bends, typical | 25 |
Tensile Strength | 113 kg | 249.122 lb |
Bending Moment | 5.423 N-m | 4 ft lb |
Flat Plate Crush Strength | 1.429 kg/mm | 80 lb/in |
Environmental specifications
Installation temperature | -5 °C to +60 °C (+23 °F to +140 °F) |
Operating Temperature | -20 °C to +80 °C (-4 °F to +176 °F) |
Storage Temperature | -20 °C to +85 °C (-4 °F to +185 °F) |
Attenuation, Ambient Temperature | 20 °C | 68 °F |
Average Power, Ambient Temperature | 40 °C | 104 °F |
Average Power, Inner Conductor Temperature | 100 °C | 212 °F |
Fire Retardancy Test Method | NFPA 262/CATVP/CMP |
Packaging and weights
Cable weight | 0.253 kg/m | 0.17 lb/ft |
Regulatory compliance/certifications
Agency | Classification |
CHINA-ROHS
![]() |
Below maximum concentration value |
c(ETL)us Certification
![]() |
CATVP/CMP |
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
ROHS | Compliant |
UK-ROHS | Compliant |
UL/ETL Certification
![]() |
CATVP/CMP |
REACH-SVHC | Compliant as per SVHC revision on www.andrew.com/ProductCompliance |